Chapter 7: Roof Assembly
Figure 7-24 Recommended lifting points for a Double A-frame section
A Purlin clip
The A-frame rafter section has two configurations: with X-bracing and without. The number of A-frame
rafter sections with X-bracing depends on which size bin is being constructed.
DANGER
All lifting should be performed by a certified crane operator with prior bin
construction experience. Never lift during windy conditions.
General Guidelines:
Construct the A-frame sections on flat ground or blocking.
Install the temperature cable brackets at the same time you assemble the A-frame sections.
Always be aware of the orientation of each part prior to assembling.
Use the correct hardware for the part being assembled. Never substitute hardware.
Always ensure hardware is tightened prior to lifting.
Always practice safety when assembling rafter sections. Be aware of others around you when
moving long A-frame sections.
Use evenly distributed connection points of support when lifting.
Before attempting a lift, adjust each lifting cable to achieve the appropriate angle needed (approxi-
mately 30 degrees).
Assemble the A-frames with X-bracing last, so that they can be easily accessed to be lifted into place
first.
Pneg-4075G 75 Ft Diameter 40-Series Bin 101