Grain-systems Tanks PNEG-4075G User Manual Page 157

  • Download
  • Add to my manuals
  • Print
  • Page
    / 170
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 156
Chapter 8: Accessories
E
Measurement from edge of sidewall sheet
to center line of baffle chute, 75 in. (190.5
cm)
K
Typical spacing, approximately 8 in. (20.32 cm)
F
Inside of bin
8. Tighten hardware to the recommended torque specifications. See Bolt Torque Specifications, page
24.
Installing the Sidedraw Discharge Chute
The following instructions discribe the installation of the sidedraw discharge chute.
What You Should Know
Field cutting is required to create the opening for the discharge chute. Cutting the opening will require two
sidewall panels to be modified.
1. Find the column of bolt holes (A) located on either side of the last baffle chute (B). Measure approxi-
mately 11 in. (27.94 cm) (C) inward on the last baffle chute (B), and place a mark or scribe.
2. Repeat this procedure from the opposite column of bolt holes (A), creating the center line (D) on the
baffle chute (B), and transfer this center line (D) onto the sidewall panel.
Pneg-4075G 75 Ft Diameter 40-Series Bin 157
Page view 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 169 170