Chapter 4: Assembling Sidewall Sheets
Figure 4-2 Standard and quad punched sidewall sheets as viewed from the outside
A
Vertical strip of caulk
B
10 in. (25.4 cm) Horizontal strip of caulk
Before bolting the next ring into place, apply one 10 in. strip of caulk (C) on the front of the under-
lapped sheet at each joint.
Also, place a 10 in. (25.4 cm) strip of caulk (D) along the lower horizontal edge of the lapping sheet at
every vertical seam. This will fill the space that occurs between the holes caused by the overlapping
sheets.