Grain-systems Tanks PNEG-4075G User Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 170
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
Chapter 4: Assembling Sidewall Sheets
When assembling two assembled laminated sheets to each other, apply a strip of caulk (A) near the
outside edge of the outer sheet, between the outer two (2) rows of bolts and outside the last row of
bolts.
Place a strip of caulk (B) 12 in. (30.4 cm) long to each the horizontal seams.
NOTE: Before bolting the next ring into place, apply a strip of caulk 12 in. (30.4 cm) long on the front
of the under lapped sheet at each joint.
Also, a 12 in. (30.4 cm) strip of caulk is to be placed along the lower horizontal edge of the lapping
sheet at the vertical seam. This will fill the space that occurs between the holes caused by the over-
lapping sheets.
When assembling two sheets to make a laminated sheet assembly (C), apply a row of caulk all around the
vertical seam.
Use the supplied tube caulk to fill the larger gaps that occur with heavier gauges and laminated sheets.
Figure 4-5 Caulking detail for assembled laminated sidewall sheets
B
12 in. (30.4 cm) horizontal strip of caulk C Laminated sheet detail (caulk not shown)
36 Pneg-4075G 75 Ft Diameter 40-Series Bin
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 169 170