Chapter 6: Stiffeners
Close-Punch Connection for a Two-Ring Stiffener (16 Ga) to a Base
Stiffener (10–16 Ga)
Reference the following information for a close-punch connection of a two-ring stiffener (CTS-2075XX) to a
base stiffener (CTS-2115XX).
Figure 6-18 Two-Ring Stiffener (16 Ga) to a Base Stiffener (10–16 Ga) Close-Punch Connection
A Close-punch two-ring stiffener
(CTS-2075XX)
B
Close-punch base stiffener (CTS-2115XX)
C Splice (CTS-2091XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
56 Pneg-4075G 75 Ft Diameter 40-Series Bin