MAINTENANCE Tower Dryer Operations & Service
2
8. On Zimmerman Dryers equipped with the
Accutrol sweep unload metering system, check
the discharge area to insure that the area is cleaned
of stalks and old grain. Inspect the sweeps for
excessive wear.
9. On GSI Dryers equipped with the hoppered
metering system, check the hopper area and the
area around the metering drum to insure that they
are cleaned of stalks and old grain. Check the
edges of the metering drum for excessive wear.
10. Important!! The covers to the discharge
sections on both the Zimmerman and GSI Tower
dryers must be in place and clamped down at all
times when the dryer is in operation. If the cover
is off during operation, the vacuum created by the
blowers will suck foreign matter from the
discharge area and deposit it in the heat section of
the dryer plugging the inside screens of the dryer
also creating a fire hazzard.
SEE PRE-SEASON CHECKLIST AT
THE END OF THIS SECTION
PRE-SEASONAL INSPECTION AND
SERVICE
The dryer is made of weather resistant material, and is
designed to require minimum service. However, each
season we recommend the following items be checked
before the unit is used, and any damaged or question-
able parts replaced. These checks will help eliminate
possible failures, and assure dependable operation of
the equipment.
1. Shut off electrical power. Open power box and
control box, and inspect for moisture, rodent dam-
age or accumulated foreign material present. In-
spect and tighten any loose terminal connections.
Replace any damaged or deteriorated wiring.
2. Lubricate the blowers, motors, and metering sys-
tem as outlined in the Lubrication Table below.
3. Check blower belts for proper tension.
4. Inspect and clean the burner. Visually check that
no holes in the stainless steel air mixing plates are
plugged. If burner ports are plugged, clear them
with a piece of wire or a drill bit. After a period of
several years, it may become necessary to drill
out the burner ports to clear away accumulated
rust. Use a #43 drill bit to return burner ports to
their original diameter. (See burner drilling proce-
dure in the Maxon Burner area of the COMPO-
NENT MANUALS section of this book.)
(NOTE: Pre-2002 model dryers require a #47
drill bit.)
5. Check electrical connections at both the flame rod
and spark plug. Clean spark ignitor and flame
rod. Replace if necessary.
6. Check drain valve on gas train to insure that there
is no water in the gas train. Valve should always
be open when the dryer is not being used. Insure
that drain valve is closed prior to dryer operation.
7. Lubricate linkage on gas modulating valve.