13. Air Flow Support Instructions
36 PNEG-222 48' Cor-Lok and Cut-Lok Flooring
* Installation, Spacing and Quantities of Air Flow Supports Under Channel Lock Floors
NOTES:
1. Use a maximum spacing of 16" for perforated corrugated flooring.
2. The number of supports listed is based on the maximum peaked capacity of each bin.
3. Use extra single supports for split floors.
4. Extra supports are required for grain recirculating equipment. Use the manufacturer’s
recommendation for the number and spacing of extra supports. NOTE: For grain flows, air flow
supports are doubled in a 14' diameter in the center of the floor.
5. Contact a representative for air flow supports required for larger bins and deeper grain depths.
6. * Increase the number of supports by 5% when used with 6-3/4" wide mfs floor planks.
Bin Diameter - Number of Supports
Grain
Depth at
Bin Wall
(ft.)
Spacing
(in.)
18 Ft. Dia. 21 Ft. Dia. 24 Ft. Dia. 27 Ft. Dia. 30 Ft. Dia.
Full Double Single Full Double Single Full Double Single Full Double Single
Full Double Single
18' 30" 34 2 8 48 2 10 60 2 12 84 2 14 88 2 14
24' 26" 36 2 8 56 2 10 74 2 12 92 2 14 104 2 14
27' 24" 44 2 8 62 2 10 76 2 12 92 2 14 112 2 14
32' 20" 54 2 10 64 2 12 84 2 14 106 2 16 130 2 18
40' 16" 58 10 14 80 12 16 104 14 18 128 16 20 160 18 22
48' 13" 72 10 16 98 12 20 126 14 22 158 16 24 190 18 28
53' 12" 76 10 18 106 12 22 140 14 24 172 16 28 210 18 30
68' 10" 86 10 22 116 12 26 156 14 28 212 16 32 250 18 36
16' 24" and 12" 68 10 8 82 12 10 104 14 12 120 16 14 140 18 14
(for Grain Flow)
Bin Diameter - Number of Supports
Grain
Depth at
Bin Wall
(ft.)
Spacing
(in.)
33 Ft. Dia. 36 Ft. Dia. 42 Ft. Dia. 48 Ft. Dia. 60 Ft. Dia.
Full Double Single Full Double Single Full Double Single Full Double Single
Full Double Single
18' 30" 116 2 16 136 2 18 172 2 20 Use 24" Spacing Use 24" Spacing
24' 26" 124 2 16 144 2 18 200 2 20 Use 24" Spacing Use 24" Spacing
27' 24" 136 2 16 154 2 18 212 2 20 274 2 22 422 2 30
32' 20" 150 2 20 184 2 22 242 2 26 326 2 28 498 2 36
40' 16" 192 20 24 234 22 28 314 24 32 410 28 36 620 34 46
48' 13" 238 20 30 278 22 34 368 24 38 488 28 44 762 34 56
53' 12" 262 20 34 306 22 36 416 24 42 534 28 48 838 34 60
68' 10" 296 20 40 356 22 44 478 24 50 652 28 58 1024 34 72
16' 24" and 12" 168 20 16 188 20 18 264 24 20 350 28 20 N/A N/A N/A
(for Grain Flow)