12 PNEG-1735 U-Trough Direct Gear Drive Bin Sweep Auger Unload Systems
4. Installation
Installation Under Aeration Floor
1. Cut 12" x 12" (30 cm x 30 cm) opening in bin wall where unload is to exit bin. (See Figure 4A.)
2. Insert unload and center it in the bin.
3. Secure unload with anchor bolts (not supplied) to the bin foundation.
Figure 4A
Figure 4B
Do not cut across bolted seams.
Cut 12" x 12" access
through bin wall
U-Trough unload. Center
in bin and anchor to floor.
Concrete anchor
bolt